Fire-rated access panels give access to the services hidden in fire-compartmented walls and ceilings — pipework, cables, valves — without breaking the fire barrier that protects compartments and escape routes. Every one is independently fire tested and rated in minutes for how long it holds back fire.

Jupiter Blue's range runs from 60 to 120 minutes, in picture-frame and beaded formats, standard and made-to-measure — and sits within our wider access panel range, which includes non-rated options.

What size opening are you filling? Any size
1800mm
900mm
Showing 1–12 of 21 products View all
1hr Fire Rated Access Panel | Picture Frame 1-HOUR FIRE RATED

1hr Fire Rated Access Panel | Picture Frame | Picture Frame

4.91 (57)
From £26.43 Ex. VAT
Bespoke sizes available · currently 8 working days
  • Zintec Steel, white finish
  • Fits: Both Wall & Ceiling
  • Insulated: 0.78 U value
  • 34dB Acoustic reduction
View Product
1hr Fire Rated Air Tested Access Panel 1-HOUR FIRE RATED | AIR TESTED

1hr Fire Rated Air Tested Access Panel | Picture Frame

From £54.46 Ex. VAT
  • Zintec Steel, white finish
  • Fits: Both Wall & Ceiling
  • Insulated: 0.78 U value
  • 34dB Acoustic reduction
View Product
Duplex SP 120 Single Door 2hr Fire Rated Both Sides 2-HOUR FIRE RATED | Both Sides

Duplex SP 120 Single Door 2hr Fire Rated Both Sides | Picture or Beaded

5.00 (1)
From £194.00 Ex. VAT
Bespoke sizes available · currently 8 working days
  • Zintec Steel, white finish
  • Fits: Wall Only
  • Insulated: 0.55 U Value
  • 36dB Acoustic reduction
View Product
Fire rated access panel with lift out door 2-HOUR FIRE RATED

Fire rated access panel with lift out door | Picture or Beaded

From £103.00 Ex. VAT
Made to measure · currently 8 working days
  • Zintec Steel, white finish
  • Fits: Wall only
  • Insulated: Smoke test 1.23 m³/hr/lm
  • 30dB Acoustic reduction
View Product
Economy Fire Rated Access Panel 2-HOUR FIRE RATED

Economy Fire Rated Access Panel | Picture or Beaded

5.00 (1)
From £60.00 Ex. VAT
Made to measure · currently 8 working days
  • Zintec Steel, white finish
  • Fits: Wall Only
View Product
1hr Fire Rated Anti-ligature Access Panel 1-HOUR FIRE RATED

1hr Fire Rated Anti-ligature Access Panel | Picture Frame

5.00 (2)
From £87.03 Ex. VAT
Bespoke sizes available · currently 8 working days
  • Zintec Steel, white finish
  • Fits: Both Wall & Ceiling
  • 36dB Acoustic reduction
View Product
1hr Fire Rated Access Panels with Plaster Door 1-HOUR FIRE RATED | PLASTERBOARD

1hr Fire Rated Access Panels with Plaster Door | Beaded Frame

5.00 (8)
From £41.00 Ex. VAT
Bespoke sizes available · currently 8 working days
  • Zintec Steel Frame, Plasterboard Door
  • Fits: Both Wall & Ceiling
  • 21dB Acoustic reduction
View Product
90Min Fire Rated Slim Access Panel with Plaster Door (Ceiling) 90-MIN FIRE RATED

90Min Fire Rated Slim Access Panel with Plaster Door (Ceiling) | Beaded Frame

From £52.93 Ex. VAT
  • Zintec Steel Frame, Plasterboard Door
  • Fits: Ceiling Only
  • 21dB Acoustic reduction
View Product
1hr Fire Rated, Insulated & Air Tested Access Panel 1-HOUR FIRE RATED | INSULATED | AIR TES

1hr Fire Rated, Insulated & Air Tested Access Panel | Picture Frame

4.95 (20)
From £54.10 Ex. VAT
Bespoke sizes available · currently 8 working days
  • Zintec Steel, white finish
  • Fits: Both Wall & Ceiling
  • Insulated: Panels of 450mm and larger are 0.35 "U" value, below that size are 0.77 "U" value
  • 36dB Acoustic reduction
View Product
1hr Fire Rated Access Panel | Beaded Frame 1-HOUR FIRE RATED

1hr Fire Rated Access Panel | Beaded Frame | Beaded Frame

5.00 (12)
From £26.43 Ex. VAT
Bespoke sizes available · currently 8 working days
  • Zintec Steel, white finish
  • Fits: Both Wall & Ceiling
  • 34dB Acoustic reduction
View Product
1hr Fire Rated Air Tested Access Panel 1-HOUR FIRE RATED | AIR TESTED

1hr Fire Rated Air Tested Access Panel | Beaded Frame

4.72 (54)
From £54.46 Ex. VAT
  • Zintec Steel, white finish
  • Fits: Both Wall & Ceiling
  • Insulated: BS EN 1634-3 Smoke Test Approved (max 600x600mm on test specimen)
  • 34dB Acoustic reduction
View Product
1hr Fire Rated Access Panel 40dB Acoustic Reduction 1-HOUR FIRE RATED | ACOUSTIC

1hr Fire Rated Access Panel 40dB Acoustic Reduction | Picture Frame

From £61.27 Ex. VAT
  • Zintec Steel, white finish
  • Fits: Both Wall & Ceiling
  • Insulated: 0.45 U Value
  • 40dB Acoustic reduction
View Product

Why fire-rated access matters
Where services pass through a fire-compartmented wall or ceiling — a service duct, a protected escape route, a utility riser — the access point has to hold the same fire resistance as the surface around it. A fire-rated access panel does exactly that: a secure, tested door that lets you reach what's behind it without creating a weak spot in the fire barrier. Building Regulations and the project specification will normally state where one is required, and to what rating.

Ratings, formats and sizes
Our fire-rated panels are tested to BS EN 1634-1 and rated at 60, 90 or 120 minutes; many are tested from both sides (duplex), and the range extends to riser doors for larger openings. Choose a picture frame (surface-mounted, frame visible) or a beaded frame (plastered in for a near-flush finish), in standard stock sizes or made-to-measure for non-standard openings.

The widest range in the UK — in stock
We hold the UK's widest range of fire-rated access panels, with most sizes in stock and free next-working-day delivery across the range. Every panel is fully guaranteed, backed by our no-quibble money-back guarantee — and if you need help matching a panel to a specification, our product experts are on 01937 325 325.

Frequently asked questions

Which fire rating do I need — 60, 90 or 120 minutes?
The building's specification or Building Regulations will normally state the rating required, and whether the panel must resist fire from one or both sides. It depends on the compartment and its purpose — escape routes, service ducts and utility risers often carry specific requirements. If it isn't specified, check with your local Building Control before ordering.
What fire ratings does Jupiter Blue offer?
Our fire-rated access panels are independently tested to BS EN 1634-1 and available at 60, 90 and 120 minutes (up to two hours), depending on the model. Many are tested from both sides (duplex), and all comply with the relevant UK standards.
Can fire-rated access panels be painted or plastered over?
Yes — many have a smooth finish that takes paint, and beaded-frame models are designed to be plastered in, so they blend into the surrounding surface without compromising the fire rating.
Are they suitable for both domestic and commercial use?
Yes. The fire-rated range is built for both, with robust construction and compliance with the relevant UK building standards.
Do fire-rated access panels come with a guarantee?
Yes — every fire-rated access panel comes with a 2-year guarantee against manufacturing defects as standard, backed by our no-quibble money-back guarantee.
Jupiter Blue Proof, not promises Est. 2007
Parcels dispatched since 2007
1.1M+
Customer rating
4.85/5 · 2,246
UK postcodes served
63,251
Next Day Delivery success rate
97.9%
Products in range