Automatic Opening Vent (AOV) Smoke Vent with offset actuator for Access

AOV Smoke Vent comprising PVC kerb with a polycarbonate dome. AOV smoke vents with offset acuators combine smoke ventilation with access. All AOVs are designed to automatically extract smoke in the event of a fire. Typically sited on flat roofs above corridors and stairwells the vents open to an angle of 140 degrees in less than 60 seconds. The range is fully tested and certified in accordance with BS EN 12101-2. Covering standards for safety, security, non-fragility and fire safety with the full guarantee of an established, accredited UK manufacturer.
Fully certified to approved document B.

Kerb options to suit your own upstand or fitting directly onto your roof deck

100mm DF (Direct Fix) kerb - fits to an existing upstand

100mm DF kerb
Standard Actuator positioning is as shown above (left side adjacent to the hinge). If needed we can mount the actuator on the right side adjacent to the hinge (please request this at the time of placing your order). AOVs can be fitted on flat roofs with a pitch of up to 15°. The hinge side needs to be facing up the slope, please ensure you take this into consideration.


Free Area explanation for AOV Smoke Vent with PVC kerb

The size of the vent (at the smallest point) minus the area of any obstructions such as motors, ladders or grilles – how well air travels through a vent for natural ventilation:

Image showing how the free area of an AOV is measured
Coefficient of Discharge (Cv) – a value to quantify the efficiency of a smoke vent. This is calculated by a third party.

Aerodynamic Free Area

The Smoke vent size is multiplied by the Coefficient of Discharge – overall performance of the vent. This is the most important, as it is the most accurate way to quantify the performance of the smoke vent. It is used in EN12101-2, BSI & UKCA certification and also stated on NBS specs.

How to measure DF Kerb version


How to measure

Aerodynamic free area - AOV Smoke Vents with DF Kerb(Aa)Aa
Smoke Vent Size (mm) Note: Rectangular Sizes are Hinged on the Long SideDaylight free area* Size (mm)Approx. Clear opening size (mm)Roof opening area (m2)Aerodynamic free areaFree Area (m2)
CvAa m2
1050 x 1050mm900 x 900mm900 x 6500.810.480.39*0.72
1200 x 1050mm1050 x 900mm1050 x 6750.950.460.43*0.88
1200 x 1200mm1050 x 1050mm1050 x 7501.100.470.52*1.01
1350 x 1050mm1200 x 900mm1200 x 6001.080.440.48*0.99
1350 x 1200mm1200 x 1050mm1200 x 6751.260.450.57*1.16
1350 x 1350mm1200 x 1200mm1200 x 7501.440.400.67*1.34
1500 x 1050mm1350 x 900mm1350 x 5251.220.420.51*1.12
1500 x 1200mm1350 x 1050mm1350 x 6001.420.430.611.32
1500 x 1350mm1350 x 1200mm1350 x 6751.620.440.721.52
1500 x 1500mm1350 x 1350mm1350 x 7501.820.450.831.72
1650 x 1050mm1500 x 900mm1500 x 4501.350.400.54*1.26
1650 x 1200mm1500 x 1050mm1650 x 12001.580.410.65*1.48
1650 x 1350mm1500 x 1200mm1650 x 13501.800.420.761.70
1650 x 1500mm1500 x 1350mm1500 x 6752.030.380.761.92
1650 x 1650mm1500 x 1500mm1500 x 7502.250.440.992.14

* Not suitable for Stairwell use because does not achieve an Aerodynamic Free Area of more than 0.70 Aa m2 in a stairwell as per the requirement of EN 12101-2, not the grey area "free vent area" that is often quoted.

Free Area explanation for AOV Smoke Vent with DF Kerb (being fitted to existing upstand)

The size of the vent (at the smallest point) minus the area of any obstructions such as motors, ladders or grilles – how well air travels through a vent for natural ventilation:

Image showing how the free area of an AOV is measured
Coefficient of Discharge (Cv) – a value to quantify the efficiency of a smoke vent. This is calculated by a third party.

Aerodynamic Free Area

The Smoke vent size less 150mm on each dimension, multiplied by the Coefficient of Discharge – overall performance of the vent. This is the most important, as it is the most accurate way to quantify the performance of the smoke vent. It is used in EN12101-2, BSI & UKCA certification and also stated on NBS specs.

Abbreviations: Aa = Aerodynamic Free Area, Cv = Coefficient flow

Mardome Trade Electronically Operated Smoke Vent Rooflights are individual polycarbonate domes intended for easy installation on flat roofs of all modern building types to provide natural smoke and heat exhaust, as well as comfort ventilation.

Certification and Regulatory Information

  • Fire rating - achieves Class B-s1, d0 to BS EN 13501:Part 1 and deemed BROOF(t4) to BS EN 13501: Part 5 by Building Regulation
  • 72 hour battery back up in the event of power cut
  • Inclusive of wind deflectors where applicable to comply with the regs
  • Complete with a Part ""L"" compliant polycarbonate triple skin for a high thermal performance & resistance to condensation
  • Safety - achieving Class B non fragility to ACR[M]001
  • The polycarbonate skin lid with an impact resistance to EN1873 1200 joules and Class B non-fragility in accordance with ACR[M]001
  • Opens to 140° in less than 60 seconds complying the requirements of the new Smoke Vent Standard BS EN12101-2

Thermal and Acoustic data

GlazingU-Value DF KerbU-Value 365mm PVC Kerb

Acoustic Airborne Sound Index

 Double 2.0 - 2.4W/m²K 1.6 - 2.1 W/m²K20dB
 Triple 1.5 - 1.7 W/m²K 1.2 - 1.5 W/m²K22dB

General Information

  • Suitable for residential and commercial buildings
  • Thermally broken kerb (PVC)
  • Extremely secure with concealed individual fixings within security caps
  • Hinged long side (where applicable)
  • 10 year guarantee
  • CE Marked
  • Weatherproofed to the full height of the upstand
  • Designed to last in excess of 20 years under normal conditions

Operation and Options

    • Optional control panels, smoke detectors, fireman’s switches and manual control points available
    • Control panel can be activated from: Manual override switches, by dedicated smoke detectors or through integration with existing smoke detection and or fire alarm systems
    • Can be integrated into any building management system
    • Features back up battery to ensure operation in the event of no mains power

Control Panel

It is recommended that Mardome Smoke Vents are connected to the Smoke Vent control panel available from us. The control panel is designed to be used with the actuator of the Mardome Smoke Vent and provides a battery backup and additional line monitoring functionality. A Mardome Smoke Vent can be installed alongside other EN12101-10 compliant control systems but we cannot provide technical support concerning the control of the product and do not keep a list of compatible control systems. Installing with an alternative EN12101-10 control system will not affect the guarantee of the product. View control panel information here.

Specification

Material
Polycarbonate dome
Not sure which to choose? Call us on 01937 325 325 — we'll ask three quick questions and recommend the right one.
Call now
Jupiter Blue Proof, not promises Est. 2007
Parcels dispatched since 2007
1.1M+
Customer rating
4.85/5 · 2,246
UK postcodes served
63,251
Next Day Delivery success rate
97.9%
Products in range
128

Figures combine verified reviews, our live catalogue, dispatch records since 2007 and carrier-reported delivery data. Nothing here is invented.